VPL-B0632F-WK12AA VPL SERIES; KINETIX; PERMANENT MAGNET ROTARY MOTOR, MOTOR SERVO | Allen Bradley
Type number: VPL-B0632F-WK12AA, Part No.: VPLB0632FWK12AA, from manufacturer: Allen Bradley, Catagory: Kinetix VP Servo Motors Drives & Motors, VPL Low Inertia Motors
della101@163.com
Module No. | VPL-B0632F-WK12AA |
Product name | SERVO MOTOR; MP SERIES; KINETIX; PERMANENT MAGNET ROTARY MOTOR; LOW INERTIA; 240 VAC; 130 MM FRAME; 3 INCH STACK |
Product description | VPL-B0632F-WK12AA VPL SERIES; KINETIX; PERMANENT MAGNET ROTARY MOTOR, MOTOR SERVO | Allen Bradley |
Part number | VPLB0632FWK12AA |
Allen Bradley recommendation product | VPL-B0632T-WJ14AA VPL PERMANENT MAGNET ROTARY MOTOR, Servo Products | Allen Bradley |
Voltage | 230 VAC, 240 VAC, 480 VAC |
Manufacturer | Allen Bradley |
Country of origin | United States |
Warranty | 1-2 year |
Shipping Method | 1.Ship worldwide, usually 5-7 days. 2. We use DHL, FedEx, UPS,TNT |
Remark | If you need a specific firmware or series relating to VPL-B0632F-WK12AA, please call or email us, we probably have it in our large inventory. |
VPL-B0632F-WK12AA VPL SERIES; KINETIX; PERMANENT MAGNET ROTARY MOTOR, MOTOR SERVO | Allen Bradley
Common Rotary Motor Specifications
These specifications are common to all Kinetix rotary motor families.
Environmental Specifications – Kinetix Rotary Motion
Attribute | KinetixVPL and VPF | Kinetix
VPC |
Kinetix
VPH |
Kinetix
VPS |
Kinetix TLP | Kinetix MP | Kinetix RDB | Kinetix TL and TLY | Kinetix HPK | Kinetix MMA |
Temperature, ambient | 0…40 °C
(32…104 °F) |
-20…+40 °C
(-4…+104 °F) |
0…40 °C
(32…104 °F) |
-20…+40 °C (-4…+104 °F) | ||||||
Temperature, storage | -30…+40 °C
(-22…+104 °F) |
-30…+70 °C
(-22…+158 °F) |
-10…+80 °C
(+14…+176 °F) |
-30…+70 °C
(-22…+158 °F) |
-20…+50 °C (- 22…+122 °F) | |||||
Relative humidity | 5…90% | 5…95% | 20…90% | 5…95% | 5…90% | |||||
Shock(1) | 20 g peak, 6 ms duration | |||||||||
Vibration (1) | 2.5 g peak @ 30…2000 Hz | — | — |
(1) Any shock and vibration application exceeding these specifications can result in premature motor failure. Repetitive acceleration is considered vibration, not intermittent shock.
Kinetix MMA – Temp, ambient -20…+40 °C (-4…+104 °F) Temp, storage -20…+50 °C (-22…+122 °F) Relative humidity 5…90% noncondensing
Thermal Ratings – Kinetix Rotary Motion
To obtain the specified motor thermal rating do not mount the motor in an area with restricted airflow. Keep other heat producing devices away from the motor and mount the motor on a surface with heat dissipation equivalent to an aluminum heatsink attached as specified in the following table.
Heatsink Size
mm (in.) |
203 x 203 x 6.35
(8 x 8 x 0.25) |
254 x 254 x 6.35
(10 x 10 x 0.25) |
305 x 305 x 12.7
(12 x 12 x 0.50) |
305 x 305 x 25.4
(12 x 12 x 1.0) |
407 x 407 x 19.1
(16 x 16 x 0.75) |
457 x 457 x 12.7
(18 x 18 x 0.50) |
508 x 508 x 19.1
(20 x 20 x 0.75) |
533 x 533 x 25.4
(21 x 21 x 1.0) |
Motor Cat. No. | ||||||||
VPL-x063xx, VPF-x063xx, VPH-x063xx | X | – | – | – | – | – | – | – |
VPL-x075xx, VPF-x075xx, VPH-x075xx | – | X | – | – | – | – | – | – |
VPL-x100xx, VPL-x115xx, VPL-x130xx, VPL-B165xx VPF-x100xx, VPF-x115xx, VPF-x130xx, VPF-B165xx VPH-x100xx, VPH-x115xx, VPH-x130xx, VPH-B165xx VPS-B1304, VPS-B1653 |
– |
– |
X |
– |
– |
– |
– |
– |
VPC-B165xx | – | – | X | – | – | – | – | – |
VPC-B215xx | – | – | – | X | – | – | – | – |
VPC-B300xx | – | – | – | – | – | – | – | X |
MPL-x15xx | X | – | – | – | – | – | – | – |
MPL-x2xx | – | X | – | – | – | – | – | – |
MPL-x3xx, MPL-x4xx, MPL-x45xx, MPL-x5xx
MPM-xxxx, MPF-xxxx, MPS-xxxx, MDF-SBxxxx |
– | – | X | – | – | – | – | – |
MPL-B6xx | – | – | – | X | – | – | – | – |
MPL-B8xx, MPL-B9xx | – | – | – | – | – | – | – | X |
RDB-B215x | – | – | – | – | – | X | – | – |
RDB-B290x | – | – | – | – | X | – | – | – |
RDB-B410x | – | – | – | – | – | – | X | – |
TL-A1xx, TLY-A1xx | X | – | – | – | – | – | – | – |
TL-A2xx, TLY-A2xx | – | X | – | – | – | – | – | – |