VPL-A1002C-CJ14AA KINETIX; PERMANENT MAGNET ROTARY MOTOR, Servo Motor | Allen Bradley
Type number: VPL-A1002C-CJ14AA, Part No.: VPLA1002CCJ14AA, from manufacturer: Allen Bradley, Catagory: Kinetix VP Servo Motors Drives & Motors, VPL Low Inertia Motors
della101@163.com
Module No. | VPL-A1002C-CJ14AA |
Product name | 100mm Bolt Circle Frame Size, 2 (Two) Magnet Stacks, 2500 RPM Rated Speed, Single-turn … |
Product description | VPL-A1002C-CJ14AA KINETIX; PERMANENT MAGNET ROTARY MOTOR, Servo Motor | Allen Bradley |
Part number | VPLA1002CCJ14AA |
Allen Bradley recommendation product | VPL-A1002C-CK12AA VPL Low Inertia Motor | Allen Bradley |
Voltage | 230 VAC, 240 VAC, 480 VAC |
Manufacturer | Allen Bradley |
Country of origin | United States |
Warranty | 1-2 year |
Shipping Method | 1.Ship worldwide, usually 5-7 days. 2. We use DHL, FedEx, UPS,TNT |
Remark | If you need a specific firmware or series relating to VPL-A1002C-CJ14AA, please call or email us, we probably have it in our large inventory. |
VPL-A1002C-CJ14AA KINETIX; PERMANENT MAGNET ROTARY MOTOR, Servo Motor | Allen Bradley
Performance Level(PL)and Safety Integrity Level (SIL)
For safety-related control systems,Performance Level (PL),according to EN ISO 13849-1,and SIL levels,according to IEC EN 61508 and
EN 62061,include a rating of the system’s ability to perform its safety functions.All ofthe safety related components of the control system must be included in a risk assessment and the determination of the achieved levels.
Refer to the EN ISO 13849-1,IEC EN 61508,and EN 62061 standards for complete information on the requirements for PLand SIL determination.
Safety-related Parameters
A motor that is equipped with a Hiperface DSL functional safety-rated feedback sensor is designed to maintain the functional safety rating of the feedback sensor attached.The safery parameters of the feedback sensors are as follows.
Attribute | MotorCat.No. | |
VPL-xaxxxx-Wx1xAx | VPL-xxxXxx-Qx1xAx | |
Safety Integrity Level(SIL) | SIL2(IEC61508),SIL CL2 (EN 62061) | |
Probability of a Dangerous Failure per Hour (PFH) | 4.0E-081/h | 3.80 E-081/h |
Safety (ategony | (AL3(ENISQ 13849 | |
Performance level (PL) | PLd (ENISO 13849) |
Motor Installation
Motor installation must comply with all local regulations and use ofequipment and installation practices that promote safety and electromagnetic compatibility:
- Allmotorsincludc a mounting pilot for aligning the motor on a machinc
- Preferred fasteners arestainless steel.