ABB AL9-30-10 Line Contactor
AL9-30-10 24V DC
General Information
-
- Extended Product Type:
- AL9-30-10 24V DC
-
- Product ID:
- 1SBL143001R8110
-
- EAN:
- 3471522268815
-
- Catalog Description:
- AL9-30-10 24V DC Contactor
Products Categories
Product Description
-
-
- Long Description:
- AL 9 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The AL… series 1-stack 3-pole contactors are of the block type design. – Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks – Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected – Accessories: a wide range of accessories is available. AL… contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.
-
Ordering
-
- Minimum Order Quantity:
- 1 piece
-
- Customs Tariff Number:
- 85364900
Popular Downloads
-
- Data Sheet, Technical Information:
- 1SBC100122C0202_Ch02
-
- Instructions and Manuals:
- 1SBC101003M5501
-
- Dimension Diagram:
- FPTE307872
Dimensions
-
- Product Net Width:
- 44 mm
-
- Product Net Depth / Length:
- 97 mm
-
- Product Net Height:
- 78 mm
-
- Product Net Weight:
- 0.52 kg
Technical
-
- Number of Main Contacts NO:
- 3
-
- Number of Main Contacts NC:
- 0
-
- Number of Auxiliary Contacts NO:
- 1
-
- Number of Auxiliary Contacts NC:
- 0
-
- Rated Operational Voltage:
- Auxiliary Circuit 690 V
Main Circuit 690 V
-
- Rated Frequency (f):
- Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
-
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 26 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
-
- Rated Operational Current AC-1 (Ie):
- (690 V) 40 °C 25 A
(690 V) 55 °C 22 A
(690 V) 70 °C 18 A
-
- Rated Operational Current AC-3 (Ie):
- (415 V) 55 °C 9 A
(440 V) 55 °C 9 A
(500 V) 55 °C 9 A
(690 V) 55 °C 7 A
(380 / 400 V) 55 °C 9 A
(220 / 230 / 240 V) 55 °C 9
-
- Rated Operational Power AC-3 (Pe):
- (415 V) 4 kW
(440 V) 4 kW
(500 V) 5.5 kW
(690 V) 5.5 kW
(380 / 400 V) 4 kW
(220 / 230 / 240 V) 2.2 kW
-
- Rated Breaking Capacity AC-3:
- 8 x Ie AC-3
-
- Rated Making Capacity AC-3:
- 10 x Ie AC-3
-
- Rated Operational Current AC-15 (Ie):
- (500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
-
- Short-Circuit Protective Devices:
- Auxiliary Circuit – gG Type Fuses 10 A
gG Type Fuses 25 A
-
- Rated Short-time Withstand Current Low Voltage (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 50 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 60 A
for 0.1 s 140 A
for 1 s 100 A
-
- Maximum Breaking Capacity:
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 100 A
-
- Maximum Electrical Switching Frequency:
- (AC-1) 600 cycles per hour
(AC-2 / AC-4) 300 cycles per hour
(AC-3) 1200 cycles per hour
-
- Rated Operational Current DC-13 (Ie):
- (24 V) 6 / 144 A
(48 V) 2.8 / 134 A
(72 V) 2 / 144 W
(125 V) 1.1 / 138 W
(250 V) 0.55 / 138 W
-
- Rated Insulation Voltage (Ui):
- acc. to IEC 60947-4-1 1000 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
-
- Rated Impulse Withstand Voltage (Uimp):
- 8 kV
-
- Mechanical Durability:
- 10 million
-
- Maximum Mechanical Switching Frequency:
- 3600 cycles per hour
-
- Rated Control Circuit Voltage (Uc):
- DC Operation 24 V
-
- Coil Consumption:
- Average Holding Value, from Warm State 3 W
Average Pull-in Value, from Cold State 3 W
-
- Operate Time:
- Between Coil De-energization and NC Contact Closing 16 … 27 ms
Between Coil De-energization and NO Contact Opening 10 … 17 ms
Between Coil Energization and NO Contact Closing 50 … 100 ms
-
- Mounting on DIN Rail:
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
-
- Mounting by Screws (not supplied):
- 2 x M4 screws placed diagonally
-
- Connecting Capacity Main Circuit:
- Flexible with Cable End 0.75 … 2.5 mm²
Rigid Cable 1 … 4 mm²
-
- Connecting Capacity Auxiliary Circuit:
- Flexible with Cable End 0.75 … 2.5 mm²
Rigid Cable 1 … 4 mm²
-
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
-
- Connecting Terminals (delivered in open position) Main Poles:
- M 3.5 (+,-) pozidriv 2 screw with cable clamp
-
- Terminal Type:
- Screw Terminals
Technical UL/CSA
-
- General Use Rating UL/CSA:
- (600 V AC) 21 A
-
- Horsepower Rating UL/CSA:
- (200 … 208 V AC) Three Phase 2 hp
(220 … 240 V AC) Three Phase 2 hp
(440 … 480 V AC) Three Phase 5 hp
(550 … 600 V AC) Three Phase 7-1/2 hp
Environmental
-
- Ambient Air Temperature:
- Close to Contactor Fitted with Thermal O/L Relay -25 … 55 °C
Close to Contactor without Thermal O/L Relay (0.85 … 1.1 Uc) -40 … 55 °C
Close to Contactor without Thermal O/L Relay (Uc) -40 … 70 °C
Close to Contactor for Storage -60 … +80 °C
-
- Climatic Withstand:
- acc. to IEC 60068-2-30 and 60068-2-11 – UTE C 63-100 specification II
-
- Maximum Operating Altitude Permissible:
- Without Derating 3000 m
-
- Resistance to Shock acc. to IEC 60068-2-27:
- Closed, Shock Direction: A 20 g
Closed, Shock Direction: B1 15 g
Closed, Shock Direction: C1 20 g
Closed, Shock Direction: C2 14 g
Open, Shock Direction: A 10 g
Open, Shock Direction: B1 5 g
Open, Shock Direction: C1 8 g
Open, Shock Direction: C2 8 g
Shock Direction: B2 10 g
Material Compliance
-
- REACH Declaration:
- 2CMT2021-006202
-
- RoHS Information:
- 2CMT2021-006277
-
- RoHS Status:
- Following EU Directive 2011/65/EU
-
- WEEE B2C / B2B:
- Business To Business
-
- WEEE Category:
- 5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
-
- ASEFA Certificate:
- ASEFA_05003BT
-
- CB Certificate:
- CB_FR_617239A
-
- CCC Certificate:
- CCC_2012010304534830
-
- CQC Certificate:
- CQC2012010304534830
-
- Declaration of Conformity – CCC:
- 2020980304001613
-
- Declaration of Conformity – CE:
- 1SBD250804U1000
-
- Declaration of Conformity – UKCA:
- 1SBD250821U1000
-
- DNV Certificate:
- DNV_GL_TAE00001UN-1
-
- DNV GL Certificate:
- DNV_GL_TAE00001UN-1
-
- GL Certificate:
- GL_26144_05HH
-
- GOST Certificate:
- GOST_POCCFRME77B07175
-
- LOVAG Certificate:
- LOVAG_FR03021-FR03027
-
- UL Certificate:
- UL-US-L312527-1102-51017991-2
UL-CA-L312527-4102-51017991-2
-
- UL Listing Card:
- UL_E312527
Container Information
-
- Package Level 1 Units:
- 1 piece
-
- Package Level 1 Width:
- 86 mm
-
- Package Level 1 Depth / Length:
- 141 mm
-
- Package Level 1 Height:
- 51 mm
-
- Package Level 1 Gross Weight:
- 0.52 kg
-
- Package Level 1 EAN:
- 3471522268815
-
- Package Level 2 Units:
- box 28 piece
-
- Package Level 2 Gross Weight:
- 14.56 kg
-
- Package Level 3 Units:
- 336 piece
Classifications
-
- Object Classification Code:
- Q
-
- ETIM 4:
- EC000066 – Magnet contactor, AC-switching
-
- ETIM 5:
- EC000066 – Magnet contactor, AC-switching
-
- ETIM 6:
- EC000066 – Power contactor, AC switching
-
- ETIM 7:
- EC000066 – Power contactor, AC switching
-
- ETIM 8:
- EC000066 – Power contactor, AC switching
-
- eClass:
- V11.0 : 27371003
-
- UNSPSC:
- 39121529
-
- IDEA Granular Category Code (IGCC):
- 4756 >> Capacitor magnet contactor
-
- E-Number (Finland):
- 3709177
Product Catalogue
ABB AL9-30-10 Line Contactor